Senville SENE-24EL-OH vs Pioneer YN024GHFI25RPH
- Heating efficiency: the Senville SENE-24EL-OH pairing has the higher HSPF2 (11 vs 10).
- Cooling efficiency: the Senville SENE-24EL-OH pairing has the higher SEER2 (25 vs 21).
- Cold weather: at 5°F the Senville SENE-24EL-OH pairing is rated for more heat (20,000 vs 18,200 BTU/h).
- Per 1,000 heating full-load hours, the estimated electricity difference is about $40 at the U.S. average rate.
| Senville SENE-24EL-OH | Pioneer YN024GHFI25RPH | |
|---|---|---|
| Cooling BTU/h | 24,000 | 24,000 |
| SEER2 | 25 | 21 |
| EER2 | 14 | 12.5 |
| HSPF2 | 11 | 10 |
| Heat at 47°F | 24,000 | 24,000 |
| Heat at 17°F | 17,100 | 15,500 |
| Heat at 5°F | 20,000 | 18,200 |
| % of 47°F at 5°F | 83% | 76% |
| COP at 5°F | 2.2 | 1.75 |
| Cold climate | Yes | Yes |
| Refrigerant | R-454B (GWP:470 | Lower GWP) | R-410A (GWP:2088) |
| Connected | No | No |
| Most Efficient | Yes | Yes |
| Indoor unit (pairing shown) | SENE-24EL-IHH | WF024GHFI25HLH |
| AHRI ref. | 218069801 | 211583737 |
| Cool kWh/1,000 h (est.) | 960 | 1,143 |
| Heat kWh/1,000 h (est.) | 2,182 | 2,400 |
| Record | 4529645 | 2410835 |
Cost estimates: cooling kWh ≈ cooling capacity × full-load hours ÷ SEER2 ÷ 1,000; heating kWh ≈ 47°F heating capacity × full-load hours ÷ HSPF2 ÷ 1,000. "Per 1,000 full-load hours" is a yardstick for comparing systems, not a prediction of your bill; your hours depend on climate, house and settings. Rate: U.S. average residential 18.31¢/kWh (EIA, July 2026 (preliminary)).