ACiQ ACIQ-24ZPL-HP230B: certified ratings
Cooling 24,000 BTU/h · SEER2 up to 21.5 · HSPF2 up to 11.4 · up to 108% of 47°F heating capacity at 5°F · Cold climate: Yes
This outdoor unit has 4 certified indoor pairings, so it is likely a multi-zone or multi-indoor-option unit; ratings differ by pairing. Series: ACIQ. Refrigerant: R-410A. Compressor: continuously variable (inverter), per ENERGY STAR.
All certified pairings (highest HSPF2 first)
| Indoor unit | Series | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat 47°F | Heat 17°F | Heat 5°F | % of 47°F cap. at 5°F | COP 5°F | Cold climate | Refrigerant | AHRI ref. | ENERGY STAR record |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ACIQ-24W-HH-MC | ACIQ | 24,000 | 21.5 | 13 | 11.4 | 29,000 | 21,200 | 25,000 | 86% | 2.21 | Yes | R-410A (GWP:2088) | 210857298 | 2448865 |
| ACIQ-24W-HH-MB | ACIQ | 24,000 | 21.5 | 13 | 11.4 | 29,000 | 21,200 | 25,000 | 86% | 2.21 | Yes | R-410A (GWP:2088) | 207825515 | 2449906 |
| ACIQ-24FM-HH-MB | ACIQ | 24,000 | 20.5 | 11.7 | 11 | 25,000 | 19,000 | 25,000 | 100% | 2.1 | Yes | R-410A (GWP:2088) | 207825525 | 2449051 |
| ACIQ-24CD-HH-MB | ACIQ | 24,000 | 19.2 | 12 | 10.5 | 25,000 | 21,000 | 27,000 | 108% | 2 | Yes | R-410A (GWP:2088) | 207825522 | 2449058 |
"% of 47°F capacity at 5°F" = heating capacity at 5°F ÷ heating capacity at 47°F, both from the ENERGY STAR record (ENERGY STAR's cold-climate designation requires ≥70% and COP ≥1.75 at 5°F; criteria).
Rough running-cost yardstick (top-rated pairing)
| kWh per 1,000 full-load hours | Cost at U.S. avg rate | |
|---|---|---|
| Cooling (24,000 BTU/h ÷ SEER2 21.5) | 1,116 | $204 |
| Heating (29,000 BTU/h ÷ HSPF2 11.4) | 2,544 | $466 |
Cost estimates: cooling kWh ≈ cooling capacity × full-load hours ÷ SEER2 ÷ 1,000; heating kWh ≈ 47°F heating capacity × full-load hours ÷ HSPF2 ÷ 1,000. "Per 1,000 full-load hours" is a yardstick for comparing systems, not a prediction of your bill; your hours depend on climate, house and settings. Rate: U.S. average residential 18.31¢/kWh (EIA, July 2026 (preliminary)).
Estimate with your own hours and rate · Compare with another system
Similar-capacity single-zone units from other DIY brands
No single-zone DIY-brand unit in the same capacity class.
See ACiQ on the manufacturer's site (plain link, not an affiliate link)
We have not tested or installed this equipment. Data gaps: price, sound level, line-set length, warranty and installation requirements are not in ENERGY STAR data. Confirm the AHRI reference number on your quote matches a certified pairing.