Mini-Split Check

Disclosure: Manufacturer links on this site are plain links, not affiliate links yet. If that changes we may earn a commission at no cost to you, and this notice will say so. We have not tested or installed any product; ratings come from ENERGY STAR certification data, and cost figures are estimates. Not an endorsement by EPA or ENERGY STAR. Learn more.

Senville SENA-12HF-OG: certified ratings

Cooling 12,000 BTU/h · SEER2 up to 25.4 · HSPF2 up to 11.6 · up to 96% of 47°F heating capacity at 5°F · Cold climate: Yes

This outdoor unit has 5 certified indoor pairings, so it is likely a multi-zone or multi-indoor-option unit; ratings differ by pairing. Series: SENA Series. Refrigerant: R-454B. Compressor: continuously variable (inverter), per ENERGY STAR.

All certified pairings (highest HSPF2 first)

Indoor unitSeriesCooling BTU/hSEER2EER2HSPF2Heat 47°FHeat 17°FHeat 5°F% of 47°F cap. at 5°FCOP 5°FCold climateRefrigerantAHRI ref.ENERGY STAR record
SENA-12HF-ICGSENA Series12,00022.212.511.612,00010,00011,50096%2YesR-454B (GWP:470 | Lower GWP)2157353053630052
SENA-12HF-IGGSENA Series12,00025.413.410.512,00012,00011,50096%1.8YesR-454B (GWP:470 | Lower GWP)2157352963630043
SENA-12HF-IFGSENA Series12,0002512.510.512,0009,80011,30094%1.88YesR-454B (GWP:470 | Lower GWP)2157353083630055
SENA-12HF-IDGSENA Series12,00020121012,5009,60011,80094%1.9YesR-454B (GWP:470 | Lower GWP)2157353013630048
SENA-12HF-1WCGSENA Series12,00023131012,5009,60011,50092%2YesR-454B (GWP:470 | Lower GWP)2166235943893584

"% of 47°F capacity at 5°F" = heating capacity at 5°F ÷ heating capacity at 47°F, both from the ENERGY STAR record (ENERGY STAR's cold-climate designation requires ≥70% and COP ≥1.75 at 5°F; criteria).

Rough running-cost yardstick (top-rated pairing)

kWh per 1,000 full-load hoursCost at U.S. avg rate
Cooling (12,000 BTU/h ÷ SEER2 22.2)541$99
Heating (12,000 BTU/h ÷ HSPF2 11.6)1,034$189

Cost estimates: cooling kWh ≈ cooling capacity × full-load hours ÷ SEER2 ÷ 1,000; heating kWh ≈ 47°F heating capacity × full-load hours ÷ HSPF2 ÷ 1,000. "Per 1,000 full-load hours" is a yardstick for comparing systems, not a prediction of your bill; your hours depend on climate, house and settings. Rate: U.S. average residential 18.31¢/kWh (EIA, July 2026 (preliminary)).

Estimate with your own hours and rate · Compare with another system

Similar-capacity single-zone units from other DIY brands

No single-zone DIY-brand unit in the same capacity class.

All Senville units

See Senville on the manufacturer's site (plain link, not an affiliate link)

We have not tested or installed this equipment. Data gaps: price, sound level, line-set length, warranty and installation requirements are not in ENERGY STAR data. Confirm the AHRI reference number on your quote matches a certified pairing.